Perceptive Biosystems/Applied Biosystems/ABI Voyager DE-STR MALDI-TOF

Title: Perceptive Biosystems/Applied Biosystems/ABI Voyager DE-STR MALDI-TOF
Company: International Equipment Trading Ltd.
Location: Vernon Hills, Illinois, USA
Email: info@ietltd.com
Click here for further information on this classified
Description:

Perceptive Biosystems/Applied Biosystems/ABI Voyager DE-STR MALDI-TOF mass spectrometer s/n# 4062 complete with LeCroy high-speed signal digitizer, Tatung monitor, Dell Optiplex GS110 CPU with keyboard, mouse, joystick, monitor, and AB Voyager 5.1 software with Data Explorer. Refurbished and decomissioned by ABI Service in 2007. Sold guaranteed installable not including the cost of installation.

SPECIFICATIONS:

  • Sensitivity - Routine detection of 5fmol of neurotensin with a signal to noise ratio > 80:1.
  • Mass Accuracy [Linear Mode] - better than 0.05% for angiotensin [1,296.6853] and myoglobin [16,952.5] with external calibration.
  • Mass Accuracy [Reflector Mode] - better than 0.008% for angiotensin and ACTH 18-39 with external calibration.
  • Mass Resolution [Linear Mode] - >3,500 for ACTH 18.39 [m/z 2,465.1989], >1,000 for myoglobin [m/z 16,952] and >100 for BSA [m/z 66,431].
  • Mass Resolution [Reflector Mode] - >10,000 for insulin (m/z 5,734) and >20,000 for ACTH 18-39.

Instrument Features:

  • A high performance Matrix-Assisted Laser Desorption Ionization Time-of-Flight (MALDI-TOF) system which is a proven technology for the MS analysis of both organic and inorganic compounds and biomolecule characterization.
  • With its 3-meter effective flight path, reflector mode and patented Delayed Extraction® (DE) technology, the Voyager is still regarded as the industry standard for superior spectral quality, delivering high resolution, sensitivity, and exceptional mass accuracy.
  • Voyager Version 5 with Data Explorer ™ software permits flexible acquisition and data processing in both positive and negative ion modes of operation to characterize complex mixtures and determine molecular weight on sub-picomole samples.
  • Post-source decay (PSD) and collision-induced dissociation (CID) options provide more structural information.
  • Fully automated acquisition and processing of data is possible for higher throughput.

Please contact us for complete used and refurbished ABI voyager system, warranty and service contract details.

Close Date: October 1, 2015
Phone: +1 (847) 913-0777
Email: info@ietltd.com
Click here for further information on this classified