Posted in | News | Nanoanalysis

Analytik Reports on the NPL's Use of the CPS Instruments Disc Centrifuge System for Nanoparticle Characterisation

Analytik, leading suppliers of innovative analytical instrumentation, report on the use of the CPS Instruments Disc Centrifuge in the Surface and Nanoanalysis group at the National Physical Laboratory, Teddington, UK.

NPL's Nia Bell with the CPS disk centrifuge system for nanoparticle size characterisation

The Surface and Nanoanalysis research group studies the physical and chemical properties of surfaces and nanomaterials, including biological samples and electronic components. NPL supplies a range of measurement services, reference materials, and software, which underpin quantitative surface analysis. Among the measurement services offered is nanoparticle sizing for which a suite of particle sizing techniques are employed.

One of the techniques used is Differential Centrifugal Sedimentation or DCS. DCS is used to obtain ultra-high resolution size distributions of particles in the nano- and micron- range. The size range of the particles that can be analysed by DCS depends on the density of their constituent materials.

Group member Nia Bell describes how she uses DCS. "We have used DCS to size particles and check for aggregation. We have also combined the density dependent information from DCS to density independent information from other techniques to investigate particle porosity and the functionalisation of particle surfaces. I have looked at silica and gold particles while other members of the group have looked at cerium oxide, titanium dioxide and zinc oxide particles amongst others."

Bell then continued to describe the density measurements in more detail: "DCS was used to investigate the adsorption of protein on gold nanoparticles. With increasing protein shell thickness the effective density of the particles decreased. For accurate interpretation of the DCS data this variable effective density had to be considered. Either the density of the shell was assumed to be equal to some constant value and the shell thickness extracted from the DCS data, or the shell thickness was assumed to be that measured using a density independent technique and DCS used to calculate the density of the shell. From the density and thickness of the protein shell, the amount of protein adsorbed could be estimated."

Other particle sizing techniques used in the laboratory include Dynamic Light Scattering, DLS, and Nanoparticle Tracking Analysis, NTA. Bell explains how they are used: "In the past DLS was the standard technique for most solution based particle sizing measurements, however, with the advent of DCS and NTA we are able to tailor our measurements better to individual samples. DCS is normally at least as quick as NTA and DLS so it is used routinely."

The CPS Instrument performs nanoparticle size analysis utilising the Differential Centrifugal Sedimentation method. This offers the unique ability to resolve very close multimodal particle distributions and to distinguish extremely small shifts in particle size. Rather than using a predictive algorithm, the instrument physically separates the nanoparticles and then measures them as they pass a light source detector and thus provides full characterisation in real time. To find out more about CPS nanoparticle size characterisation solutions, visit: www.analytik.co.uk.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Analytik Ltd. (2019, February 11). Analytik Reports on the NPL's Use of the CPS Instruments Disc Centrifuge System for Nanoparticle Characterisation. AZoNano. Retrieved on April 18, 2024 from https://www.azonano.com/news.aspx?newsID=25894.

  • MLA

    Analytik Ltd. "Analytik Reports on the NPL's Use of the CPS Instruments Disc Centrifuge System for Nanoparticle Characterisation". AZoNano. 18 April 2024. <https://www.azonano.com/news.aspx?newsID=25894>.

  • Chicago

    Analytik Ltd. "Analytik Reports on the NPL's Use of the CPS Instruments Disc Centrifuge System for Nanoparticle Characterisation". AZoNano. https://www.azonano.com/news.aspx?newsID=25894. (accessed April 18, 2024).

  • Harvard

    Analytik Ltd. 2019. Analytik Reports on the NPL's Use of the CPS Instruments Disc Centrifuge System for Nanoparticle Characterisation. AZoNano, viewed 18 April 2024, https://www.azonano.com/news.aspx?newsID=25894.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.