Micropore Size Analysis of Porous Carbons Using CO2 Adsorption at 273.15 K (0 °C)

Activated carbons in the form of fibers, pellets, granules, and powders are used in air filters, water purification systems, for removing organic impurities from various solutions, as well as in a variety of medical, environmental, and agricultural applications. These highly microporous, high surface area materials are often characterized by their apparent BET surface area and their pore size distribution (PSD). Measuring the PSD of microporous samples using nitrogen or argon adsorption is a slow process, requiring very low vacuum levels that require an expensive turbomolecular pump. Alternatively, the PSD can be determined quickly using carbon dioxide at 0°C, at higher pressures than using nitrogen or argon, thus increasing throughput and reducing the equipment cost.

Why Measure Pore Size Distribution of Porous Carbons?

The pore size distribution (PSD) is a key factor in characterizing porous materials. The PSD analysis can be useful in developing new porous materials for specific applications as well as for testing of existing products. Traditionally, the PSD of a porous solid is evaluated from the analysis of nitrogen or argon adsorption isotherms measured at 77.4 K or 87.3 K, respectively. It is well-known, however, that at such cryogenic temperatures, diffusion of adsorptive molecules into carbon micropores is very slow. Moreover, it was pointed out that diffusional limitations at this temperature might influence adsorption in ultra-micropores (pores smaller than 7 Å (0.7 nm)).

For porous carbons, usually containing a wide distribution of pore sizes including ultra-micropores, these diffusional limitations lead to time-consuming measurements and may cause under-equilibration of measured adsorption isotherms, giving erroneous results for the PSD. It has long been recognized that problems of this type can be eliminated by using CO2 adsorption at 273.15 K (0°C).

Which Instrument is Used?

Although it is possible to perform these measurements on the Autosorb iQ and the Quadrasorb evo, the low cost and ease of use of the NOVAtouch make this a preferred choice for this technique. The 0°C temperature can be maintained using a wide-mouth dewar, filled with an ice/water mixture; however, more stable temperature control can be maintained using a circulating chiller and jacketed vessel (recirculating dewar) filled with a suitable coolant (usually an antifreeze/water mixture). In either case, the liquid level is maintained using a water level float switch.

Which Samples are Tested?

Activated carbon fiber, ACF-10 (Nippon Kynol, Japan), and BPL granular activated carbon (Calgon Carbon, USA) were chosen as representative materials for this report. This method can be reliably applied to a wide variety of nanoporous carbons; provided the material under study does not have a significant number of surface functional groups, which can interact with the quadrupole moment of CO2 and affect the results.

Want to know more? Click here to read the full article.

This information has been sourced, reviewed and adapted from materials provided by Anton Paar GmbH.

For more information on this source, please visit Anton Paar GmbH.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Anton Paar GmbH. (2020, June 15). Micropore Size Analysis of Porous Carbons Using CO2 Adsorption at 273.15 K (0 °C). AZoNano. Retrieved on October 31, 2024 from https://www.azonano.com/article.aspx?ArticleID=5256.

  • MLA

    Anton Paar GmbH. "Micropore Size Analysis of Porous Carbons Using CO2 Adsorption at 273.15 K (0 °C)". AZoNano. 31 October 2024. <https://www.azonano.com/article.aspx?ArticleID=5256>.

  • Chicago

    Anton Paar GmbH. "Micropore Size Analysis of Porous Carbons Using CO2 Adsorption at 273.15 K (0 °C)". AZoNano. https://www.azonano.com/article.aspx?ArticleID=5256. (accessed October 31, 2024).

  • Harvard

    Anton Paar GmbH. 2020. Micropore Size Analysis of Porous Carbons Using CO2 Adsorption at 273.15 K (0 °C). AZoNano, viewed 31 October 2024, https://www.azonano.com/article.aspx?ArticleID=5256.

Ask A Question

Do you have a question you'd like to ask regarding this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.