New Microsensor Answers Relation Between Cell Mass and Growth Rate in Cancer Cells

University of Illinois researchers are using a new kind of microsensor to answer one of the weightiest questions in biology – the relationship between cell mass and growth rate.

The team, led by electrical and computer engineering and bioengineering professor Rashid Bashir, published its results in the online early edition of the Proceedings of the National Academy of Sciences.

"It's merging micro-scale engineering and cell biology," said Bashir, who also directs the Micro and Nanotechnology Engineering Laboratory at Illinois. "We can help advance biology by fabricating new tools that can be used to address important questions in cell biology, cancer research and tissue engineering."

The mechanics of cellular growth and division are important not only for basic biology, but also for diagnostics, drug development, tissue engineering and understanding cancer. For example, documenting these processes could help identify specific drug targets to slow or stop the uncontrolled growth of cancer cells.

Biologists have long questioned whether cells grow at a fixed rate or whether growth accelerates as mass increases. Previous studies have used aggregate populations of cells, making it impossible to determine patterns of individual cell growth.

With their small, sensitive microsensors, the Illinois researchers were able to track individual colon cancer cells' masses and divisions over time, a feat never before accomplished. They found that the cells they studied did grow faster as they grew heavier, rather than growing at the same rate throughout the cell cycle.

Each microsensor is a tiny, suspended platform made in silicon on a chip. The platform is a mere 50 microns wide – half the width of a human hair. The suspended scale vibrates at a particular frequency, which changes when mass is added. As a cell's mass increases, the sensor's resonant frequency goes down.

"As you make the structure smaller and smaller, it becomes more sensitive to the mass that's placed on it," Bashir said. "A cell is a few nanograms in mass or smaller. If we can make our sensor small enough, then it becomes sensitive to cell mass."

The researchers developed an array of hundreds of sensors on a chip. They can culture cells on the chip similar to the way scientists grow cells in a dish. Thus, they can collect data from many cells at once, while still recording individual cellular measurements.

Another advantage of these microsensors is the ability to image cells with microscopes while cells grow on the sensors. Researchers can track the cells visually, opening the possibilities of tracking various cellular processes in conjunction with changes in mass.

"Imaging acts as a control. You can actually watch the cell divide and grow and correlate that to your measurements. It really validates what you have," Bashir said. "There are lots of optical measurements that now you can integrate with mass sensing."

Through measurements of live and fixed cells, the researchers were also able to extract physical properties such as stiffness through mathematical modeling. Some cell types are stiffer than others; for example, bone cells are more firm, while neurons are more gelatinous. Mechanical science and engineering professors Narayana Aluru and K. Jimmy Hsia, co-authors of the paper, performed extensive analytical and numerical simulation to reveal how cell stiffness and contact area affect mass measurement.

Next, the researchers plan to extend the study to other cell lines, and explore more optical measurements and fluorescent markers.

"These technologies can also be used for diagnostic purposes, or for screening. For example, we could study cell growth and mass and changes in the cell structure based on drugs or chemicals," Bashir said.

Source: http://illinois.edu/

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    University of Illinois at Urbana-Champaign. (2019, February 13). New Microsensor Answers Relation Between Cell Mass and Growth Rate in Cancer Cells. AZoNano. Retrieved on December 11, 2024 from https://www.azonano.com/news.aspx?newsID=20540.

  • MLA

    University of Illinois at Urbana-Champaign. "New Microsensor Answers Relation Between Cell Mass and Growth Rate in Cancer Cells". AZoNano. 11 December 2024. <https://www.azonano.com/news.aspx?newsID=20540>.

  • Chicago

    University of Illinois at Urbana-Champaign. "New Microsensor Answers Relation Between Cell Mass and Growth Rate in Cancer Cells". AZoNano. https://www.azonano.com/news.aspx?newsID=20540. (accessed December 11, 2024).

  • Harvard

    University of Illinois at Urbana-Champaign. 2019. New Microsensor Answers Relation Between Cell Mass and Growth Rate in Cancer Cells. AZoNano, viewed 11 December 2024, https://www.azonano.com/news.aspx?newsID=20540.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.