Thought Leaders

Electron Microscope Based Fabrication and Nano-Mechanical Testing

The early research involving manipulation and nano-mechanical testing of individual nanostructures was demonstrated by use of atomic force microscope (AFM) and scanning tunneling microscope (STM) based systems [1-4]. For the first time, these microscopes allowed sub-nanometer scale observation as well as interaction with the specimen. Most of the work involving fundamental mechanical properties of nanotubes was done by AFM based surface manipulations on a planar substrate. Using a sharp microscopy tip, individual nanotubes could be located and transported by rolling and sliding; ultimately they could be cut to the right size (by pushing). These microscopes offer advantage in terms of the resolution but there is one major downside to any AFM/STM based manipulation strategy; the lack of real-time imaging and the limitation of manipulation to planar surfaces, which makes some operations impossible.

In the last few years, scanning electron microscope (SEM), focused ion beam microscope (FIB) and transmission electron microscope (TEM) based nano-manipulation systems have started to replace the AFM (based systems) [5-8]. SEM/FIB offers 3-D manipulation of the nano-structures in real time. The more spacious chamber of this kind of microscope allows mounting of bigger specimen. Although the resolution provided by a SEM is an order of magnitude less than that of a TEM or an AFM, it usually is considered good enough for selection, separation, manipulation, assembly as well as testing of nano-mechanical devices.

Our research group has been involved in SEM and FIB based manipulation for fundamental mechanical property evaluation as well as fabrication of ‘proof-of-principle’ devices. Since the whole fabrication and testing is carried out under direct view of SEM, there remains little chance for ambiguity in the experimental data. Dr. Singh and his team [7-8] have demonstrated fabrication and testing to two individual nanotube (NT) based devices: a) an individual NT/sphere device for use as a force sensor [7] and b) a prototype microtome CNT nano-knife for sectioning of biological materials [8].

Nano-devices fabricated and tested by use of a SEM based nanomanipulation system. (a) NT/sphere force sensor device, see reference [7] for details. (b) Carbon nanotube prototype nano-knife

Figure 1. Nano-devices fabricated and tested by use of a SEM based nanomanipulation system. (a) NT/sphere force sensor device, see reference [7] for details. (b) Carbon nanotube prototype nano-knife, see reference [8] for details.

The NT/sphere device incorporates a polystyrene microsphere bead attached to an individual multi-walled carbon nanotube (MWCNT), shown in Fig. 1(a). The device has applications in studying cell deformation behavior by measuring the deflection of the sphere optically, since the sphere is large enough to be detected accurately with optical methods [7,9]. We have continued to work with research groups at National Institute of standards and Technology (Materials Reliability and Optoelectronics Division) to explore new applications of this device and so far we have been able to demonstrate: (a) calibration of the sensor to much lower the range of forces i.e., piconewton and (b) Utilizing the NT/sphere arrangement for emulating a cell nucleus for calibration studies using optical coherence tomography (OCT) [9].

The prototype nano-knife device consists of a CNT stretched between two tungsten needles (held together on a glass substrate). In-situ transverse load tests on the nano-knife indicated that failure was at the weld (the CNT was unaffected by the force applied), shown in Fig. 1(b). Measured device strength was ~0.14 GPa, corresponding to a weld breaking force of ~10-7 N. While the cutting experiments performed on a gold-coated epon resin specimen (biological cell plasticizer) showed indentation marks due to the NT [7].

MEMS based tensile tester stretching an individual MWCNT (left) and corresponding stress-strain plot (right)

Figure 2. MEMS based tensile tester stretching an individual MWCNT (left) and corresponding stress-strain plot (right), see reference [10] for more details.

Our current research at Nanoscience and Engineering Lab at Kansas State University is focused on synthesis and mechanical testing of polymer-derived ceramic SiCN-Carbon nanotube composite nanowires [11-12]. Polymer-derived ceramics are unique, as they have been shown to exhibit mixed properties of polymers, ceramics and graphene in general. We are developing ways to experimentally determine the mechanical strength of individual nanowires using MEMS based tensile platform (collaboration with Dr. Victor Bright of University of Colorado at Boulder). We have previously demonstrated the tensile testing capabilities of such a MEMS tester in which an individual MWCNT was stretched to fracture demonstrating typical telescopic mode of failure in MWCNTs, Fig. 2 [10]. Bending tests are being performed by use an AFM-based system inside SEM, similar to reference [7].

In conclusion, the introduction of SEM-based manipulation systems into engineering research has enhanced our understanding of the nano-mechanical phenomenon in 1-D nanostructures as well as opened new avenues for fabrication of various prototype nanoscale devices. This will have major effect in shaping the future of nanotechnology research.

Acknowledgements

Gurpreet Singh would like to thank Kansas State University for start-up funds for related research currently being performed in our lab.

References

  1. E. W. Wong, P. E. Sheehan, and C. M. Lieber. Nanobeam mechanics: elasticity, strength, and toughness of nanorods and nanotubes. Science 277, 1971 (1997).
  2. M. R. Falvo, G. J. Clary, R. M. Taylor II, V. Chi, F. P. Brooks, Jr., S. Washburn, and R. Superfine. Bending and buckling of carbon nanotubes under large strain. Nature (London) 389: 582 (1997).
  3. Collins PG, Zettl A, Bando H, Thess A and Smalley RE. Nanotube nanodevice. Science 278 (5335): 100-103 (1997).
  4. Tombler TW, Zhou CW, Alexseyev L, Kong J, Dai HJ, Lei L, Jayanthi CS, Tang MJ and Wu SY. Reversible electromechanical characteristics of carbon nanotubes under local-probe manipulation. Nature 405 (6788): 769-772 (2000).
  5. M. F. Yu, O. Lourie, M. J. Dyer, K. Moloni, T. F. Kelley, and R. S. Ruoff. Strength and breaking mechanism of multiwalled carbon nanotubes under tensile load. Science 287: 637 (2000).
  6. Zhu and Espinosa. An electromechanical material testing system for in situ electron microscopy and applications. Proc. National Academy of Sciences 102: 14503 (2005).
  7. G. Singh, P. Rice, and R. L. Mahajan. Fabrication and mechanical characterization of a force sensor based on an individual carbon nanotube. Nanotechnology 18 475501 (2007).
  8. G. Singh, P. Rice, R.L. Mahajan, and J.R. McIntosh. Fabrication and characterization of a CNT based nano-knife. Nanotechnology, 20 095701 (2009).
  9. T. Dennis, S. Dyer, A. Dienstfrey, G. Singh, and P. Rice. Analyzing quantitative light scattering spectra of phantoms measured with optical coherence tomography. Journal of Biomedical Optics, 13, 024004 (2008).
  10. J.J. Brown, J.W. Suk, G. Singh, A.I. Baca, D.A. Dikin, R.S. Ruoff, and V.M. Bright. Microsystem for nanofiber electromechanical measurements. Sensors and Actuators A: Physical, Volume 155, Issue 1 Pg 1-7 (2009).
  11. J.H. Lehman, K.E. Hurst, G. Singh, E. Mansfield, J.D. Perkins, and C.L. Cromer. Core–shell composite of SiCN and multiwalled carbon nanotubes from toluene dispersion. Journal of Materials Science 45:4251–4254 (2010).
  12. G. Singh, S. Priya, M. Hossu, S. R. Shah, S. Grover, Ali R Koymen, and R. L. Mahajan. Synthesis, electrical and magnetic characterization of core-shell carbon nanotube – SiCN nanowires. Materials Letters, Volume 63, Issue 28, Pg 2435-2438: (2009).

Disclaimer: The views expressed here are those of the interviewee and do not necessarily represent the views of AZoM.com Limited (T/A) AZoNetwork, the owner and operator of this website. This disclaimer forms part of the Terms and Conditions of use of this website.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Singh, Gurpreet. (2019, July 15). Electron Microscope Based Fabrication and Nano-Mechanical Testing. AZoNano. Retrieved on April 18, 2024 from https://www.azonano.com/article.aspx?ArticleID=2848.

  • MLA

    Singh, Gurpreet. "Electron Microscope Based Fabrication and Nano-Mechanical Testing". AZoNano. 18 April 2024. <https://www.azonano.com/article.aspx?ArticleID=2848>.

  • Chicago

    Singh, Gurpreet. "Electron Microscope Based Fabrication and Nano-Mechanical Testing". AZoNano. https://www.azonano.com/article.aspx?ArticleID=2848. (accessed April 18, 2024).

  • Harvard

    Singh, Gurpreet. 2019. Electron Microscope Based Fabrication and Nano-Mechanical Testing. AZoNano, viewed 18 April 2024, https://www.azonano.com/article.aspx?ArticleID=2848.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.