New Magnetoelectric Sensors for Deep Brain Stimulation

Up to now, the brain's magnetic field is measurable only under technical laboratory conditions. This technique is therefore not feasible in terms of the broader medical use, although it would be significant for diagnosing numerous conditions such as epilepsy and dementia, or even for improving therapies such as deep brain stimulation for treating Parkinson's disease. Three research teams at Kiel University (Germany) have now jointly developed a new type of magnetoelectric sensor, which is intended to allow the use of this important technology in the future. The scientific breakthrough: As opposed to conventional magnetoelectric measuring techniques, the new sensors operate at normal conditions. Neither cooling nor external magnetic bias fields are required. A new article in Nature Materials describes the design and properties of these so-called exchange biased magnetoelectric composite materials.

"Our composites with exchange biasing present an international milestone in the research of magnetoelectric materials", says Professor Eckhard Quandt, senior author of the study and spokesperson of the Collaborative Research Centre 855 Magnetoelectric Composites - Future Biomagnetic Interfaces (CRC 855). "By eliminating the dependence on externally applied magnetic bias fields, we have removed a significant obstacle for the medical application of magnetoelectric sensors such as magnetocardiography and magnetoencephalography". As the sensors do not affect one another due to their particular design, measuring arrays made up of hundreds of units are now conceivable. This would enable the production of flow maps of heart currents or brain waves.

The new composites consist of a complex sequence of around a hundred layers of material, each of which is only a few nanometres thick. The magnetoelectric sensors contain both magnetostrictive and piezoelectric layers which, on the one hand, deform due to a magnetic field to be measured and, as a result of this, at the same time produce electrical voltage which is used as the measuring signal. Enno Lage who has been working on the study since 2010 explains its background: "With the conventional magnetoelectric layer systems it is only possible to perform such highly sensitive measurements if the sensor is subjected to a bias magnetic field.

"What makes our composites so extraordinary are antiferromagnetic supporting layers made of manganese iridium, which act like magnetic fields inside the material", he adds. "This means that the bias field for the measurement is produced directly in the sensor and no longer needs to be provided externally." A complete sensor is usually a few millimetres in size and contains a multi-layer of this new material, which is approximately a thousandth of a millimetre thick. The new composite materials have been produced in the recently established Kiel Nano Laboratory's cleanroom. "These types of sensor systems can only be produced successfully in this particle-free environment", says Dr. Dirk Meyners, who is scientifically supervising Lage during the doctoral degree programme.

With this step in the development towards removing the dependence of magnetoelectric measurements on external magnetic bias fields, the working groups led by Lorenz Kienle, Reinhard Knöchel and Eckhard Quandt have achieved an important objective of the CRC 855, which has been supported by the German Research Foundation since January 2010. The CRC's overall aim is to develop such new materials and to implement them into a fully functional, biomagnetic interface between men and the outside world. Quandt indicates future prospects: "Beyond the CRC's opportunities, in the Cluster of Excellence Materials for Life, which is currently being reviewed, we could promote a range of further applications on the basis of these composites, for example, as sensors for non-invasive brain stimulation."

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.